Views: 0 Author: Site Editor Publish Time: 2026-11-25 Origin: Site
A gear pump is a positive-displacement pump that carries fluid from an inlet to an outlet in spaces formed by rotating gears and the housing. In a hydraulic circuit, gear displacement and shaft speed determine theoretical flow. The load and circuit restrictions determine the pressure the pump must work against. To select a gear pump, start with the flow you need at operating speed, then verify the pump’s pressure, inlet and mounting limits on the exact model drawing.
In an external gear pump, the prime mover turns a drive gear. A second gear meshes with it and rotates in the opposite direction. As the teeth disengage at the inlet, the volume available to the fluid increases. The pressure difference between the supply and the inlet fills those spaces. Fluid travels around the outside of the gears between the teeth and the housing. At the outlet, the teeth reengage and displace the fluid into the discharge port. Viking Pump external gear pump demonstration
Flow path in a typical external gear pump
Inlet → teeth separate and the cavities fill.
Outer perimeter → filled cavities move around each gear.
Outlet → teeth reengage and displace fluid into the discharge line.
The center mesh separates the high-pressure and low-pressure sides. The working clearances at the gear tips and end faces allow some fluid to leak back inside the unit. That leakage becomes easier to see as the oil warms or pressure across the pump rises. A worn pump can deliver acceptable flow with the circuit unloaded and fall short when a cylinder moves against a load.
Part | What it does | What matters when comparing replacements |
|---|---|---|
Drive gear and shaft | Receive mechanical power from the prime mover | Spline or key geometry, shaft engagement and permitted loads |
Driven gear | Rotates with the drive gear and carries fluid around the case | Gear width and tooth design are part of the manufacturer’s displacement and performance design |
Housing and ports | Contain the gears and route fluid into and out of the pumping chambers | Port position, thread or flange standard and clearance for hoses |
Bushings or bearings and side plates | Support the gears and maintain operating clearances | Approved oil, operating pressure and wear condition |
Shaft seal and static seals | Keep fluid inside and help prevent air from entering | Fluid compatibility, approved temperature range and seal configuration |
An external gear pump uses two gears with teeth on their outer surfaces. An internal gear pump uses an externally toothed gear inside a larger gear with inward-facing teeth. Some internal designs use a crescent-shaped separator to divide the inlet and outlet sides. The geometry affects how the pump fills, how much flow pulsation the circuit sees and what the manufacturer can specify for viscosity, speed and pressure. Viking Pump overview of gear and vane pumping principles
For a fixed-speed auxiliary circuit, start by checking an external design against required flow at the hottest expected oil temperature. For a noise-sensitive installation or a viscous fluid transfer duty, compare the internal design’s published noise or inlet data at your operating conditions. Use the flow and noise comparison in BLINCE’s guide to internal vs external gear pumps to decide which catalog limits to check first.
Theoretical flow in liters per minute equals displacement in cubic centimeters per revolution multiplied by shaft speed in revolutions per minute, divided by 1,000. Actual flow can be estimated by multiplying theoretical flow by volumetric efficiency at the intended operating point.
For example, a 16 cm³/rev pump at 1,500 rpm displaces 24 L/min in theory. If the assumed volumetric efficiency is 90%, estimated delivery is 21.6 L/min. A circuit needing 22 L/min at its working pressure would fall short with these assumptions. The 90% figure is an example input. Use the manufacturer’s curve or a qualified flow measurement for a purchase decision.
Engine-driven machines need an additional check at low working rpm. On a power take-off with a 0.8:1 pump-to-engine speed ratio, an engine running at 1,500 rpm drives the pump at 1,200 rpm. The same 16 cm³/rev pump then delivers a theoretical 19.2 L/min. Use pump shaft speed in the calculation and compare it with the specific pump’s minimum speed at load.
Record normal operating pressure and the duration and frequency of any peaks. A catalog can show different continuous and intermittent limits for different displacements within a single frame. Verify the working point, including speed and oil state, against the relevant displacement row. Parker PGP500 fixed-displacement gear pump catalog
A pump supplying 22 L/min at a pressure differential of 150 bar transfers about 5.5 kW of hydraulic power. The drive must supply more because leakage and mechanical losses consume power. Evaluate the drive under steady operation and startup, especially when oil is cold. Check the manufacturer’s inlet pressure and viscosity limits and use the circuit designer’s approved overpressure protection.
Provide the shaft-end view used by the manufacturer to define clockwise or counterclockwise rotation. Confirm the pilot diameter, bolt pattern, spline dimensions and port sealing standards on the same drawing revision. Hose routing matters too. A port that clears a frame rail on a rear-port pump can face the rail on a side-port replacement.
The BLINCE hydraulic gear pump rotation guide explains how to reconcile a rotation arrow with the shaft-end view.
Start with the BLINCE SGP hydraulic gear pump product page if you are replacing an SGP1 or SGP2. Identify the family on the nameplate and check the complete configuration against the machine drawing.
The SGP gear pump technical catalog describes the SGP2A external gear design and its automatic axial-clearance compensation. It gives different dimensional drawings for side-port and flange-port configurations. Use the specific port drawing to check the connection and available clearance.
For a small fixed-speed power unit, check the HGP series hydraulic gear pump against the mounting drawing and the calculated flow at the actual drive speed.
If you’re preparing an RFQ for repeat orders, the hydraulic gear pump supplier selection guide sets out what to send with the drawing and how to compare offers.
Gear pumps commonly supply hydraulic power units, lubrication circuits and auxiliary functions on mobile machinery. A fixed-speed power unit may use a gear pump to move a cylinder through a repeatable cycle. A mobile machine can use a separate gear pump to supply an auxiliary circuit with a defined flow range. In fluid transfer, some gear pumps handle viscous liquids, subject to the specific design’s approved speed, fluid and inlet conditions. Size a pump for the circuit it serves, particularly when one machine has both a high-pressure work circuit and a lower-pressure auxiliary circuit.
If a pump is noisy only on cold startup, have a qualified technician check oil condition and the inlet path against the manufacturer’s requirements. Cold oil, an inlet restriction and air ingress can produce overlapping symptoms. If the unit is quiet but loses loaded flow as the oil warms, compare unloaded and loaded readings at documented speed and temperature. A relief valve bypassing under load can mimic pump wear. Isolate and depressurize the equipment according to the manufacturer’s procedure before disturbing any hydraulic connection.
Yes. A gear pump has a defined geometric displacement per revolution. Delivered flow depends on speed and internal leakage. Pressure rises as the circuit resists the flow, up to the operating limits of the equipment and its pressure controls.
Use a model explicitly rated for bidirectional operation for a reversing duty. A conventional unit may have direction-specific inlet or seal arrangements. Confirm the approved direction and port function from the manufacturer’s drawing.
Send the full nameplate and photos of the shaft, mounting face and ports. Include equipment model, pump rotation from the shaft end, pump shaft speed, oil type and operating flow and pressure if they are known. Ask the supplier to return a drawing and model code that can be checked against the machine before approval.
Tel: +86 132 4232 1601
✉️ Email: info@blince.com
Website: https://blince.com/
This article is a general engineering guide. Final component selection should be based on machine drawings, measured hydraulic data, working conditions, safety requirements, and confirmation from a qualified hydraulic engineer or supplier.
Blince Hydraulic is an industry-leading company dedicated to precision-engineered fluid power manufacturing and custom hydraulic solutions. Backed by decades of deep field expertise in industrial machinery and thousands of successful global deployments, our engineering team focuses entirely on high-performance hydraulic component manufacturing, including specialized orbital motors, high-pressure travel drives motor, and robust directional control valves. Our production infrastructure utilizes state-of-the-art multi-axis CNC machining systems and is fully ISO 9001 certified to guarantee repeatable volumetric accuracy across every single manufacturing run.
We deliver fast, highly dependable, and cost-efficient hydraulic solutions to heavy industry distributors, machinery OEMs, and maintenance crews across more than 150 countries. Whether your active project calls for a small-volume batch of customized shaft profiles or a large-scale production run of severe-duty cast iron gear pump, we configure our flexible production schedules to meet your target lead times with total pricing predictability. Partnering with Blince means securing maximum system efficiency, elite material quality, and uncompromised fluid power professionalism.
To learn more about our complete product lineup, visit our official website: www.blince.com.