A press can need very little oil for its final stroke and still demand high pressure. Before you slow its external gear pump with a VFD, check three things at that loaded speed. Can the pump run continuously there? Does it deliver enough flow with hot oil? Can the electric motor and drive sustain the shaft torque? The lowest usable speed is the lowest point that satisfies all three for the intended duty.
A variable frequency drive, or VFD, changes the speed of the electric motor driving the pump. It can reduce the oil a fixed-displacement pump delivers while the machine moves slowly. It also changes the motor’s cooling and may take the pump into a part of its operating range that the original machine never used. Before specifying a replacement or commissioning the retrofit, write down the slowest loaded operating point you actually expect. That is a more useful starting point than a frequency setting someone used on a different machine.
An external gear pump moves an approximately fixed geometric volume per shaft revolution. At a given speed, clearances inside the pump allow some oil to leak internally. How much reaches the circuit therefore depends on operating conditions, including pressure and oil viscosity. Pressure rises in response to resistance and loading in the circuit. At the same required pressure, slowing the shaft reduces theoretical flow while the torque needed for each revolution can stay substantial.
Write down the work sequence before reading a data sheet. A small power unit might start unloaded, advance a cylinder rapidly, press at a low speed, hold for a set time, and retract. A fixture can spend a long time clamped with little motion. A lubrication or cooling branch may still need a minimum flow while the main actuator is idle. These are separate conditions. For each one, record the required flow into the branch, working pressure at the pump, oil temperature, and time spent there.
Point in the cycle | What to record | Why it changes the decision |
|---|---|---|
Cold start | Minimum oil temperature, approximate viscosity, intended speed and whether the pump starts loaded | Thick oil can raise inlet restriction and starting demand |
Fast approach or return | Highest flow, time at that flow and pump differential pressure | Determines the upper required speed and whether the inlet and drive can support it |
Slow work at operating temperature | Required delivered flow, pressure, oil temperature and minutes per cycle | The pump can reach its lower speed limit while the motor still carries substantial torque |
Hold or standby | Pressure, leakage compensation, unloading path, auxiliary demand and restart frequency | Determines whether the supply must run continuously or can stop under a suitable circuit design |
Transitions | Pressure peaks, acceleration, deceleration and recovery time | Reveals short events that steady gauge and average current readings can miss |
Use the shaft speed at the pump. A drive may display hertz or an estimated motor speed. Induction motor slip, an intervening gearbox or a belt reduction can change the relationship to the pump. When the assembly is direct-coupled, confirm the speed under load with the machine’s feedback or a suitable measurement method. With a reduction drive, record its ratio and the speed at each end. Put rpm, bar and L/min on the inquiry form so the pump supplier can compare them with the relevant curve.
Calculate the usable range for each mode. The lower bound must satisfy pump speed, delivered flow and motor loadability together. Any maximum for speed, inlet, circuit flow, torque, power or temperature can set the upper bound. Both ends can move when the oil warms, the pressure changes or the machine starts a different mode. A single minimum and maximum rpm on a commissioning sheet needs the conditions beside it.
Start with three quantities. Pump displacement is the geometric volume moved in one revolution, in cm³/rev. Volumetric efficiency represents delivered flow divided by theoretical flow at a specified point. Mechanical efficiency accounts for the shaft torque required above the ideal pressure-related torque. Treat both efficiencies as conditions of the calculation. Ask for a hot-oil curve or test data for the candidate build before accepting either estimate.
Delivered flow (L/min) ≈ displacement (cm³/rev) × pump speed (rpm) × volumetric efficiency ÷ 1,000.
Pump input torque (N·m) ≈ displacement (cm³/rev) × pump differential pressure (bar) ÷ (20 × π × mechanical efficiency).
Pump shaft power (kW) ≈ input torque (N·m) × pump speed (rpm) ÷ 9,550.
Differential pressure is outlet pressure minus inlet pressure, using consistent reference units. On a vented open circuit, pump outlet gauge pressure can be a rough planning proxy if the inlet is close to atmospheric pressure. Actual outlet and inlet readings matter when the inlet is materially below or above ambient. Catalog inlet limits may be expressed in absolute pressure, so keep the gauge reference visible on the test sheet. The Danfoss GearMe Group 2 technical manual explains these quantities and shows how speed and pressure enter a particular pump family’s limits.
Suppose a directly coupled pump on an industrial fixture has 25 cm³/rev displacement and works at a 140 bar pressure difference. Assume 0.85 mechanical efficiency at both points for this first screen. At 1,450 rpm, use a hypothetical volumetric efficiency of 0.90. At 450 rpm, use 0.80 to show what a larger leakage share might do. These are sample inputs for the arithmetic. A supplier curve could show a different result or rule out the lower point entirely.
Planning point at 140 bar | 1,450 rpm | 450 rpm |
|---|---|---|
Theoretical flow | 36.25 L/min | 11.25 L/min |
Estimated delivered flow | 32.63 L/min | 9.00 L/min |
Estimated pump input torque | 65.5 N·m | 65.5 N·m |
Estimated pump shaft power | 9.95 kW | 3.09 kW |
At the slower speed, an actuator needing 10 L/min at the pump outlet would already be short by 1 L/min in this example. If the 10 L/min is required at the actuator, branch flow and any external leakage need to be accounted for to translate it into an outlet requirement. In either case, the 3.09 kW at the slower point can be misleading when considered alone. The electric motor must still deliver roughly 65.5 N·m for as long as the high-pressure portion lasts. An electric motor capable of roughly that torque at its nominal speed can have less continuous torque available at 450 rpm.
Pressure belongs beside speed on the quote. With the same pump and assumed mechanical efficiency, at a 30 bar differential the calculated input torque would be about 14.0 N·m. A low-pressure jog test at that point says little about whether the motor can run at low speed during the 140 bar operation. Conversely, a peak pressure event needs to be matched to its own duration, speed, drive overload capacity and pump rating. Put the real pairs of pressure and speed in the request so the manufacturer can compare the conditions that occur together.
With those same assumptions, a 10 L/min outlet requirement would put the flow estimate at 500 rpm: 10 × 1,000 ÷ (25 × 0.80). Compare that estimate with the manufacturer’s loaded minimum. If the specified minimum is higher, check delivered flow at the approved speed and whether the circuit can handle any surplus. Verify the new point with the supplier’s curve because the 0.80 efficiency in this example can change with speed.
Theoretical flow gives a clean reference for a condition that can otherwise look ambiguous on the machine. Imagine a calibrated measurement near the pump shows 12 L/min at 600 rpm with the oil hot. With the same 25 cm³/rev displacement, theoretical flow is 15 L/min and the indicated delivered fraction is 80%. If the reading comes from a line downstream of a bypass or another consumer, it describes that branch. Establish where the flow goes before attributing the gap to internal leakage.
For a worn replacement candidate, the supplier needs comparable readings at the original pump’s actual speed, the same oil temperature, and at least one representative pressure. A change in flow between a warm low-pressure test and a hot high-pressure run combines several effects. Pairing readings under controlled conditions helps distinguish reduced shaft speed, internal leakage and external flow diversion. Include both the measured value and the location of each instrument on a simple schematic.
A catalog may show that minimum operating speed rises with pressure for a particular design. A figure appearing in a summary table may have a speed, fluid, temperature, displacement or pressure condition in a footnote. Ask for the exact model and shaft option before relying on it. A lower speed accepted during a short transition gives different evidence from a speed the pump can sustain during every pressing cycle. Request continuous and short-duration limits separately.
Hot oil generally has lower viscosity than the same fluid when cold. At lower shaft speed, the geometric flow available each minute is smaller. Any leakage at the intended pressure then takes a larger fraction of what the pump could deliver. Low flow, an increase in housing temperature or a slowing cylinder can justify investigation, but each has multiple possible causes. A cylinder might slow because a valve is bypassing or because pressure relief flow rises as the circuit warms. A pump flow measurement paired with load pressure and oil temperature is more informative than machine speed alone.
Use the operating viscosity range specified for the pump. Take the oil grade and expected temperature range from the actual application. If the tank temperature is the only known reading, ask whether it represents the pump inlet during the slow segment. Where a supplier needs viscosity, ask for the fluid’s viscosity-temperature data and state where and when temperature was measured. Oil substitutions can alter both the warm leakage picture and the cold inlet margin. They need to match the machine and component requirements.
Warm loaded operation is often the question at the low end. Cold oil and a rapid run-up have their own constraints at the high end. An installation that works once the tank warms may have excessive inlet vacuum when it starts after a weekend shutdown. Hoses, filters or strainers specified by the installation, tank level and suction lift contribute to that check. If the pump is fitted above the reservoir or the inlet was rerouted for the retrofit, provide a dimensioned drawing.
At the high-speed working point, check actual pump flow against the common supply and return paths, including the valve, filter and cooler. Ask about continuous and short-duration ratings, and whether the highest pressure and speed can occur together. If the size change raises maximum flow, the highest rpm the VFD can command may no longer be usable even though the electric motor can reach it. Record the measured pressure at the inlet with its units and reference, especially at the highest planned flow and the normal cold start.
A supplier can use those conditions to rule out a frame before quoting it. The Rexroth external gear unit selector begins technical preselection with flow, pressure and speed, then adds rotation, drive shaft, cover and line connections. For an existing power unit, the useful version of that process includes both ends of the speed range and the associated pressure and temperature.
Many electric motors use a fan on the motor shaft to cool the housing. At low rpm, the fan moves less air. The motor may have to be derated, which means reducing the torque it can carry continuously under those conditions. A separately powered blower can help on a compatible motor, subject to the combination’s ratings and the manufacturer’s advice. The motor-loadability section of ABB’s drive dimensioning guide shows why the selection needs a torque-versus-speed view and the actual cooling arrangement.
Ask the motor supplier for allowable continuous shaft torque at the slow, loaded point and the highest expected ambient temperature. Also ask about the starting and short-term duty. Provide the VFD model, power supply, carrier frequency or other configured conditions if requested, and motor nameplate. Compare drive output current in the intended duty to the drive’s continuous and overload limits after applicable derating. Drive current helps identify stress, but current alone does not confirm winding temperature or the pump’s pressure and flow.
Shaft power is pump input power at the coupling. Electric demand upstream of the motor and drive also includes losses in those components. Use measured electrical input over the duty cycle if the project needs an energy case. Reduced shaft speed may lower average power where excess oil previously crossed a valve. A machine that stays at high pressure, needs cooling or auxiliary flow, or adds a blower has a different balance. A single low-speed reading cannot establish annual energy savings.
If a retrofit trips as it accelerates, note which branch is pressurized and how long the drive remains in overload. Verify the sequence against the machine’s drawing. A loaded restart can demand more than a normal unloaded start, and the drive’s short-time rating can matter even when steady operation is comfortable. Ask whether a restart after a jam, interrupted cycle or loss of power is part of the design requirement.
A motor that runs normally at first and reaches its thermal limit after extended low-speed work points to a different investigation. Bring the time plots for pump speed, pressure and drive current together with the available temperature readings. Look for a slow segment that gets proportionally longer on the heaviest jobs. If the pump’s permitted minimum speed also rises at the same pressure, correcting only the cooling or only the pump can leave the other restriction in place.
Above base speed, verify that the motor and drive still provide the torque needed. Some combinations enter a field-weakening region where available torque decreases with speed. The pump can also hit its own high-speed limit or an inlet restriction first. The BLINCE guide to getting more hydraulic flow covers that end of the selection separately.
A good retrofit has a speed window wide enough for the machine’s required loaded conditions. If the current pump has that window and passes the motor and drive checks, retaining it is a reasonable quote baseline. Ask whether the allowed operating points apply to the exact part code and oil. If the machine needs lower delivered flow than the pump can make at its permitted minimum, find out whether another displacement or a different flow-control strategy provides the better fit.
Using the example above, a smaller displacement would let the pump spin faster at the same low-flow requirement, provided its efficiency were comparable. It also reduces pressure-related shaft torque for a given differential pressure. The tradeoff appears on fast approach, when the smaller pump needs higher speed to deliver the original flow. Ask about both conditions and redraw the package if the new pump needs different port locations, shaft engagement or a larger inlet line. Use the manufacturer’s curve to compare actual flow for each candidate.
A circuit that meters a small branch while the pump runs at an approved speed may suit a short slow segment. Ask the machine designer to check where the surplus flow goes, how much energy becomes heat and how the pressure is controlled. A long hold phase may warrant evaluating unloading or a designed stop-and-restart strategy if the machine can maintain the required function and safety in that state. If the requirement combines sustained high-pressure holding or very wide flow variation with strict thermal limits, a variable-displacement pump may merit a separate comparison. It changes the control scheme and installation requirements.
What the evidence shows | What to compare on the quote |
|---|---|
Pump and electric motor both clear the slow loaded point | Retain the pump and confirm its conditions, VFD settings and acceptance readings |
Pump can run there but delivered flow is short | Compare approved pump speed or another displacement with the full cycle |
Pump low-speed limit prevents the desired low flow | Compare smaller displacement at higher rpm with an approved metering or unloading arrangement |
Motor thermal rating is the limiting factor | Compare a motor and drive rated for the low-speed torque, including cooling configuration |
Required low and high flows cannot fit the same rated window | Review circuit design and pump alternatives before purchasing a drop-in part |
Suppose the original fixture has two operating modes. In the short cycle, the slow loaded segment lasts 12 seconds. In the long cycle, it can repeat with almost no time at the fast setting. A solution that survives the short cycle can accumulate heat over the long one. Require the quote to say which regime the listed performance covers. Where a change affects pressure control, stored energy or actuator holding, have the responsible machine designer review it against the original safety design.
A photo of the nameplate gives the supplier a starting point. Add the pump serial or model code, a shaft-end view, the shaft pilot and connection measurements, port locations, and physical clearance. Say where the inlet is relative to the tank and what fluid the unit uses. For a fixed pump with several possible variants, these details help the supplier match the mounting and port arrangement before recommending a size. The BLINCE hydraulic gear pump range provides the category entry, while the HGP series gives an example of a product family to review by exact configuration.
For a repeatable inquiry, name the normal hot slow point and the maximum-flow point first. Give speed in rpm at the pump shaft, outlet and inlet readings when available, delivered flow, oil temperature and duration. Add an estimate of the longest standby and distinguish the lowest normal oil level from the tank’s full condition if it affects the inlet. Include the cold start and highest repeated pressure separately. A person pricing the pump can then see which data are measured and which values must be established by the proposed model.
Ask the supplier to return a dimensioned drawing, the full ordering code and the acceptable continuous speed at the submitted pressure and oil condition. Ask for expected outlet flow and input torque at the slow and high-flow points, the approved pressure and speed combinations, and the inlet limits. Request the test conditions with any published figures. Have the electric drive supplier confirm continuous torque and overload capacity for the installed motor and VFD pair. That puts the mechanical and electrical evidence next to the hydraulic data before the order is placed.
When the parts are delivered, use an agreed commissioning record. Under the original machine’s applicable procedures, the responsible technician can record the approved cold-start sequence, hot slow point and maximum-flow point. Agree which measurements, instrument locations and tolerances define acceptance. Leave a named person responsible for any discrepancy between delivered flow, required pressure and motor current. Before signing off, compare the loaded readings against the acceptance limits agreed on the quote.
Send the cycle, measurements and pump drawing to BLINCE for a gear pump configuration review. Include which parts must stay on the machine and whether the opportunity is a replacement, a trial retrofit or an OEM build. Ask for the missing model-specific values to be listed with the quotation.
The usable lower frequency depends on the relationship between VFD frequency and pump shaft rpm, the pump’s rated conditions, and the electric motor’s loadability. A model may have an approved rpm at one pressure and a higher minimum under load. Convert the intended frequency to actual shaft speed and check the model under working pressure and viscosity.
For a given valve state and machine load, the circuit can still demand the same pressure at lower flow. Ideal torque then follows displacement and differential pressure. Lower speed reduces shaft power at that torque. In practice, changing speed can alter available flow and circuit state, so verify both pressure and torque at the operating point that matters.
Use actual pump rpm, displacement and an efficiency or performance curve for the working pressure and oil condition. Frequency is useful as an operating setting after the speed relationship has been verified. A measured outlet flow at the intended duty is stronger evidence for acceptance.
A larger displacement may deliver more at the same rpm, yet it also increases the torque demand at the same pressure. It can change peak flow, heat, inlet requirements and the fit of the shaft and flange. Compare the proposed displacement across the cycle before choosing it. Make the supplier’s lowest approved loaded speed and the motor’s maximum continuous torque part of the same review.
Tel: +86 132 4232 1601
✉️ Email: info@blince.com
Website: https://blince.com/
This article is a general engineering guide. Final component selection should be based on machine drawings, measured hydraulic data, working conditions, safety requirements, and confirmation from a qualified hydraulic engineer or supplier.
Blince Hydraulic is an industry-leading company dedicated to precision-engineered fluid power manufacturing and custom hydraulic solutions. Backed by decades of deep field expertise in industrial machinery and thousands of successful global deployments, our engineering team focuses entirely on high-performance hydraulic component manufacturing, including specialized orbital motors, high-pressure travel drives motor, and robust directional control valves. Our production infrastructure utilizes state-of-the-art multi-axis CNC machining systems and is fully ISO 9001 certified to guarantee repeatable volumetric accuracy across every single manufacturing run.
We deliver fast, highly dependable, and cost-efficient hydraulic solutions to heavy industry distributors, machinery OEMs, and maintenance crews across more than 150 countries. Whether your active project calls for a small-volume batch of customized shaft profiles or a large-scale production run of severe-duty cast iron gear pump, we configure our flexible production schedules to meet your target lead times with total pricing predictability. Partnering with Blince means securing maximum system efficiency, elite material quality, and uncompromised fluid power professionalism.