Hydraulic systems rely on multi-way valves (directional control valves) to route fluid flow and control actuators. These valves come in various configurations, often described by the number of positions and ways (ports) they have. In this article, we’ll clarify what terms like “two-position three-way”and “three-position six-way”mean, and explain how multi-way valves can be arranged to create parallel and series hydraulic circuits. We’ll use clear terminology (P, T, A, B, N ports, etc.), real-world analogies, and examples to make these concepts easy to grasp for engineers, technical buyers, and fluid power learners.
Hydraulic directional valves – often solenoid-operated – control the direction, flow, and pressure of fluid in a system. They achieve this by opening, closing, or switching connections between different ports. Key terms include:
Ports (Ways): Connection points in the valve. Common port labels are P (Pressure inlet from pump), T (Tank return to reservoir), and A/B (work ports leading to a cylinder or motor). Some valves also have an N port (Next, or power beyond port) for connecting to another valve downstream. For example, a power beyond adapter in the “N” port provides a high-pressure carryover so fluid can feed another valve bank.
Positions: Distinct spool positions inside the valve that change flow paths. A two-position valve has two stable states (often one energized and one de-energized), while a three-position valve has three (typically two extremes plus a center neutral). Springs are commonly used to return the spool to a center or default position when not actuated.
Understanding a valve’s designation (e.g. “3/2” for a two-position three-way valve or “6/3” for a three-position six-way valve) is crucial for designing hydraulic circuits. The first number denotes the ways (ports) and the second the positions. Let’s break down these examples in detail.

A two-position three-way valve is a directional valve with three ports and two spool positions. In industry shorthand this is a 3/2 valve. It essentially functions like an on/off switch for fluid going to an actuator. One position (say, when a solenoid is energized or a lever is shifted) connects the pressure port to an outlet port, allowing fluid flow to the actuator. The other position typically cuts off the supply and vents the actuator to the tank. In other words, when the valve is “open”, fluid can flow through in one direction; when “closed”, the flow is blocked and the actuator may be connected to return.
Use case: A classic application is controlling a single-acting cylinder or any device that needs a supply and an exhaust. For example, on a hydraulic press with a spring-return cylinder, a 3/2 solenoid valve can direct pressurized oil (P) to the cylinder port (A) to extend it, and when de-energized, connect that port A to tank (T) so the cylinder retracts by spring force. One can think of it like a three-port faucet diverter: in one position it sends fluid to the cylinder, and in the other it dumps the flow out to tank (allowing the cylinder to collapse).
Two-position three-way valves are often solenoid valves for automation, but they can be mechanically or pneumatically actuated as well. They have only two states – for instance, energized vs. de-energized – so they’re straightforward for on/off control of fluid flow. In practice, they might be designated “normally closed” (blocking flow until actuated) or “normally open” (allowing flow until actuated to block), depending on how the internal spool is configured.
A three-position six-way valve is more complex, with six ports and three spool positions (commonly noted as 6/3 valve). This configuration is less common than standard 4-way valves, but it provides extra ports for more elaborate flow control. Essentially, a 3-position 6-way valve can manage multiple flow paths or even multiple actuators from one valve by its internal porting design. It’s like having two interconnected valves in one housing, giving flexibility to create advanced circuits.
To visualize, consider that a typical 4-way valve (for a double-acting cylinder) has P, T, A, B ports. Now a 6-way valve adds two more ports (often labeled something like P2 and T2 or N and an extra return). These additional ports can serve as secondary inputs/outputs or a power-beyond pathway. In many cases, a 6-way valve is designed so that it can be linked with other valves easily. One set of P/T ports might connect to the primary pump and tank, and the extra P2/T2 ports can feed or receive flow from another valve stage. This allows multiple such valves to be connected in series or parallel as needed.
For example, Festo offers a manual lever 3-position 6-way valve for hydraulic training systems. In its neutral center position (spring-centered), it opens a path from the primary pressure inlet to the primary tank (unloading the pump) while blocking the secondary ports and work ports (P1 → T1 is open, while P2, T2, A, B are all closed). This means when the valve is centered, no actuator moves and the pump flow simply goes to tank at low pressure (idle). The two active positions of the valve can then route flow to achieve different functions or connect different circuits. One position might direct flow from P1 to A and B to T1 (like extending a cylinder), while another could connect P1 to B and A to T1 (retracting the cylinder). Simultaneously, the presence of the P2 and T2 ports means this valve can pass flow to or from another valve: by linking several 6-way valves, you can implement series, parallel, or even mixed (series-parallel) circuits in a system. In essence, the extra ports give designers the freedom to chain valves or share flow without external tee fittings.
Use case: Three-position six-way valves often appear in mobile hydraulics and complex machinery. For instance, in one wheel loader design, the tilt control spool was a 3-position 6-way valve that controlled both the bucket tilt cylinder in two directions (tilt up/down) and also a third function – the bucket’s clamp or closing action – all with one valve spool. This is an advanced configuration where a single multi-way valve can manage two motions and a clamping function by clever porting in different spool positions. (Another spool on the same machine was a 4-position 6-way valve for the boom, which even had an extra float position.) These examples show that 6-way valves are used to integrate multiple hydraulic functions, often to save space and simplify the hydraulic circuit.
From a circuit design perspective, a 3-position 6-way valve is especially useful when you want an open-center neutral (to unload the pump) yet still have a way to carry pressure onward to additional valves. The extra “ways” can be configured as a carryover (power beyond) outlet and a secondary inlet. This lets you put valves in series (flow passes through one to feed the next) or in parallel (both valves draw from the supply) by how you plug or connect those ports. We will next examine what it means to connect valves in parallel vs. series and how these multi-way valve configurations enable those circuit designs.

When controlling multiple actuators (cylinders, motors) in a hydraulic system, you have two fundamental circuit arrangements available:
Parallel Circuits: Each valve/actuator branch is fed directly from the pressure supply line (and returns to tank independently). This means multiple actuators can receive flow simultaneously, sharing the pump flow. In a parallel setup, activating one function does not inherently block flow to another – fluid can take multiple paths. However, if two actuators are operated together, they will compete for flow, and typically the one with lower resistance (lighter load) will move first or faster. Parallel circuits are common in modern equipment because they allow multi-function control – for example, raising a boom while swinging an arm at the same time.
Series Circuits: The valves or actuators are arranged in line, so that fluid flows through one and then into the next. In effect, one function is downstream of another. This often means that the upstream actuator has priority – it will receive flow first, and only once it completes or builds pressure will fluid feed the next actuator. If two valves are in series and the first valve is actuated, it may divert all flow, cutting off downstream valves (until the first is satisfied or released). Series circuits tend to cause sequential operation: one actuator moves, then the next, rather than simultaneously. This can be useful for automatic sequencing of movements or for safety (ensuring one action finishes before another starts), but it can limit the ability to do two things at once.
An easy analogy is to think of electrical circuits or water flow: A parallel circuit is like plugging two appliances into the same outlet via a power strip – they can run together (though they share available power). A series circuit is like wiring appliances in a chain – the second only receives power through the first; if the first is off, the second gets nothing. In a fluid analogy, imagine two water wheels in a stream: in parallel, the stream splits and each wheel gets its own flow; in series, the water must spin the first wheel, then whatever is left goes on to spin the second. In the series case, the first wheel will take what it needs and the second gets the “leftover” flow (and if the first is jammed, the second stops entirely).
Neither approach is “better” in all cases – they simply serve different purposes. Many hydraulic systems actually use a combination: some functions in parallel, others in series, and use special valves (like sequence valves or flow dividers) to coordinate when needed. Now, let’s see how multi-way directional valves are configured for each case.
In a parallel circuit arrangement, each directional valve (or each section of a multi-spool valve bank) connects to the supply pressure independently. Practically, this means all P ports of the valves are tied to a common pressure line (manifold) from the pump, and all T ports return to the tank line. When none of the valves are actuated, fluid (from a fixed-displacement pump in an open-center system) typically circulates through an open-center path to tank. The moment any one spool shifts to power a cylinder, it blocks that center bypass and directs flow into the parallel paths of the valve assembly. Oil is then available to all actuators in the parallel network. If multiple spools are moved at once, the flow will divide – although not always equally. Usually, the actuator with the least load (least resistance) will move first as it allows easier flow, a phenomenon known as the “path of least resistance” effect. Operators often observe this as one function slowing down when another, heavier load function, is simultaneously operated – the lighter load steals flow until its resistance rises.
Valve design for parallel circuits: Modern multi-section valves are frequently built with parallel circuitry (sometimes called “parallel center” design). This ensures that when one section is activated, downstream sections still have access to pressure. For example, many excavators and loaders use parallel valve banks so the driver can multi-task movements. If more than one function is engaged, the pump flow is distributed and often a pressure compensator or flow control is used to even out speeds. In an uncompensated parallel circuit, if two spools are open, all flow might go to one actuator until it encounters enough load, then the other starts – this is why lift and curl functions can interact. Various solutions like flow-sharing valves or load-sensing systems are added to address that, but fundamentally the parallel layout is what allows simultaneous operation.
Setting up a parallel circuit with discrete valves is straightforward: connect all P ports together to the pump (or a common high-pressure gallery) and all T ports together to the tank return. Each valve’s work ports go to its respective cylinder or motor. If using multi-way valves with an N port (power beyond), you typically install a plug that converts the valve to open-center parallel flow (so that in neutral the flow goes out the T port to tank, not out the N). In a parallel config, the N port may either be blocked off or used for a separate purpose (like feeding an accessory only when the main functions are inactive). Many standard hydraulic monoblock valves are by default parallel: for instance, “parallel circuit” is the common design, whereas a “tandem (series) circuit” might be a special option.
Benefits of parallel circuits: The big advantage is independent control – actuators don’t have to move in a fixed sequence. You can start or stop any motion regardless of others (subject to pump capacity). It’s ideal when you want a machine to perform combined actions, like steering while driving, or lifting an implement while extending it. The downside is the flow-sharing issue; if one actuator demands low pressure and high flow, it can starve another. Designers mitigate this with flow control valves, priority valves, or load-sensing pumps to ensure each function gets the flow it needs. Still, parallel circuits are the go-to for multi-actuator systems requiring flexibility.

In a series circuit arrangement, valves are connected one after another such that the outlet of one feeds the inlet of the next. To picture this, imagine the pressure line from the pump going into Valve 1’s P port; then the flow that exits Valve 1 (when in neutral) goes into Valve 2’s P port, and so on. The power beyond (N) port on a valve is the key to making this happen – it carries high-pressure flow onward to the next valve in line while the original valve still has its own return-to-tank path for when it operates. By installing a power beyond adapter in a valve’s outlet section, you isolate the flow: high-pressure flow goes out the N port to feed downstream valves, and the T port on that valve handles only low-pressure tank return. In essence, the N port becomes the series continuation of the pressure line.
When valves (or sections) are in series like this, the one closest to the pump has priority. Fluid flows through each valve in turn. If the first valve is actuated, it typically redirects the pump flow into its actuator and blocks the flow from reaching further (until that first valve’s demand is met or it is returned to neutral). Only when Valve 1 is in neutral does flow freely pass to Valve 2 (and then Valve 2 can use it). If Valve 1 is partially open (throttling), Valve 2 may only get whatever excess flow (or pressure) is not used by 1. This is why series circuits inherently create a sequential or priority-based control. For example, if you plumb two lift cylinders in series via valves, the first one might extend completely before the second one moves, ensuring an orderly sequence (this could be desirable in applications like deploying outriggers one after the other).
Valve design for series circuits: Open-center valves with a tandem center (series) spool are used in classic fixed-pump systems. In neutral, each valve passes fluid to the next as if through a continuous pipe to tank. When a valve is actuated, its spool cuts off the downstream flow path (prioritizing its function). For instance, older tractor loaders often had the loader valve bank in series with the backhoe valve – engaging the loader could steal flow from the backhoe unless the loader spool was neutral. To implement a series circuit with modern modular valves, you use the carryover (power beyond) port. The first valve’s N (next) port feeds the inlet of the second valve, whose N port feeds the third, and so on, with only the last valve’s outlet going to tank. Each valve in the chain must be equipped for power beyond so it can handle the full pump flow internally without damage (i.e. a sleeve or adapter is installed). The importance of the N port is highlighted by manufacturers: it’s specifically meant “to make connection between two control valves” as a high-pressure carryover link.
Benefits and considerations of series circuits: The primary advantage is that you can easily create a priority or sequence control without extra sequencing valves – the upstream function naturally has priority. Series connection also simplifies plumbing in systems where only one function is expected to operate at a time (the flow just cascades down when each upstream valve is satisfied). It can reduce the number of hoses from a pump (one line in, one line out from a chain of valves). However, there are important considerations and drawbacks:
Sequential operation: As noted, simultaneous operation is limited or impossible without special pressure-compensating valves. In many cases this is a disadvantage because it limits multitasking. It’s used deliberately only when one-after-another actuation is desired or acceptable. Otherwise, designers prefer parallel or load-sensing systems for modern machinery to allow combined movements.
Pressure drop and heat: Pushing fluid through multiple valves in series can cause cumulative pressure drops. Each valve and its internal passages add resistance. By the time fluid reaches a downstream valve, its available pressure may be reduced (especially if an upstream function is in use). The unused energy turns into heat. Thus, series circuits can be less efficient if multiple valves are frequently active or if long flow paths are used.
Valve capacity matching: When linking valves in series, ensure each valve can handle the full system flow and pressure. All the flow for subsequent actuators goes through the upstream valves’ galleries. If the flow rate exceeds what those valves are rated for, you risk pressure losses, valve damage, or unstable operation (e.g. spool jamming or leaks). Likewise, each valve in series will see pressure from both its own load and any downstream loads stacking up. If one section is set to a lower pressure, it could starve downstream functions or cause them to stall. Proper selection and calibration of valves (matching flow/pressure specs and relief settings) is essential for safe, efficient series operation.
Complexity and maintenance: A series arrangement means the system is interdependent – a failure or leak in one valve can affect all downstream functions. There are more connections in a chain, increasing complexity. Regular maintenance and checks for pressure settings, leaks, and contamination are important. Still, the series approach can save space (fewer pump lines) and cost (simpler pump or single relief valve for the chain), so it’s a trade-off.
Example application: Consider a hydraulic lift with two stages that must raise sequentially. By connecting the cylinder control valves in series, the first stage will extend fully before pressure builds enough to drive the second stage – achieving a simple sequencing without electronic controls. In another case, the Chinese manual for a wheel loader noted that its multi-way valve had a series circuit design internally to control the boom and tilt cylinders, locking each part in position as needed. This ensured that when neither spool is active, both cylinders stay put (closed centers) and pump flow goes to tank (open center passage), and when one spool is active it diverts flow for that function while the other function remains locked. Such designs illustrate how series circuits can meet specific operational requirements for safety or simplicity.

With an understanding of parallel vs. series, we can summarize how multi-way valves help achieve each:
Parallel Circuit Setup: Use valves (or a multi-spool valve manifold) with a common pressure feed. In a monoblock or sectional valve assembly, choose a parallel configuration so that shifting any spool directs flow to that section while maintaining supply to others. Ensure the pump can supply the combined flow if multiple functions run together. If needed, include flow control valves or load-sensing to manage flow splitting between branches. All return lines go to tank. (Think of each valve as a branch off a main line.)
Series Circuit Setup: Link valves using the power beyond (carryover) feature. The output (N port) of the first valve feeds the inlet of the next, and so forth. Use tandem-center or open-center spools that allow flow-through in neutral. Set the most priority-critical function as the first in line. Verify each valve’s ratings for full pump flow. Optionally, add a sequence valve or pressure-adjustable valve if you need a precise pressure threshold for switching from one function to the next (to fine-tune the sequencing). All intermediate valves should have their tank ports only handling their own return flow, not the full pump flow. The last valve in the series dumps to tank at the end of the chain. (Think of each valve as a link in a chain, handing off flow to the next.)
Combined Circuits: Some systems use a hybrid. For example, two valves might run in parallel (both getting pump flow) while a third is fed downstream of those via a sequence – effectively a series-parallel mix. Multi-way valve assemblies (like the 6-way valves discussed) enable this by providing multiple ports to interconnect valves creatively. An engineer might connect certain ports to set up one part of the circuit in series and another in parallel. The goal is to ensure each actuator gets the right flow at the right time. For complex systems, manifold blocks are often designed with internal passages to achieve the desired network of series/parallel paths.
Understanding the terminology “two-position three-way” and “three-position six-way” is fundamental when selecting or discussing hydraulic valves. A 3/2 valve offers a simple two-state control for single-line actuators or pilot signals, whereas a 6/3 valve provides a multi-port, multi-state solution for more complex flow routing, often including the capability to easily configure series or parallel circuits by how valves are linked.
When designing a hydraulic circuit, deciding between a parallel vs. series configuration (or a combination) will drastically affect how the machine operates. Parallel circuits enable simultaneous, independent motion at the cost of flow sharing, making them common in systems requiring multitasking. Series circuits enforce sequential operation and priority, which can simplify certain controls but limit concurrent movement. Multi-way directional valves, especially those with advanced porting like an N port for power beyond, are the building blocks that let engineers implement these circuits in practice – from a simple solenoid valve controlling one cylinder, to a multi-spool manifold orchestrating an entire piece of heavy equipment.
By using the proper valve type and configuration, and paying attention to flow control and sequential control needs, designers can ensure the hydraulic system behaves as intended. For instance, if two cylinders must move together, a parallel valve setup with flow controls might be chosen; if one must always move before the other, a series link or a sequence valve achieves that. Always consider the system’s load demands, safety (e.g. holding positions, which may require closed centers or lock valves), and the potential need for future expansion (adding another valve downstream via power beyond, for example). With a solid grasp of these concepts and terms, one can read hydraulic schematics or spec sheets with confidence and make informed decisions in fluid power design.
Q1: What is a two-position three-way valve in a hydraulic system?
A two-position three-way valve (also called a 3/2 directional valve) is a type of hydraulic directional valve with three ports and two stable operating positions. It is commonly used to control single-acting cylinders or pilot lines, allowing fluid to flow in one position and venting to tank in the other. These valves are often solenoid- or manually actuated and are suitable for simple on/off fluid control tasks.
Q2: What does a three-position six-way directional valve do?
A three-position six-way valve (6/3 valve) is a multifunctional directional valve with six ports and three spool positions. It enables complex flow routing, often including center-neutral unloading and power beyond configurations for multi-actuator control. These valves are typically used in systems requiring sequential or mixed parallel-series control, such as loaders or integrated hydraulic modules.
Q3: What is the difference between series and parallel hydraulic circuits?
In a parallel hydraulic circuit, multiple actuators receive fluid from a shared pressure line, allowing simultaneous movement. In a series hydraulic circuit, flow passes from one valve or actuator to the next, creating a sequential or prioritized control effect. Series circuits are ideal for operations requiring step-by-step motion; parallel circuits support independent, simultaneous function.
Q4: How does a hydraulic valve power beyond (N port) connection work?
The N port, also known as the power beyond port, allows a directional valve to pass high-pressure fluid to downstream valves in a series hydraulic configuration. When using the N port, the valve is configured with a power beyond adapter to split pressure and return flow paths, enabling chained valve operation without starving subsequent actuators.
Q5: Can I connect the T (tank) port of one valve to the P (pressure) port of the next in a hydraulic circuit?
No, directly connecting the T port of one valve to the P port of the next is incorrect in most hydraulic systems. The tank port is a low-pressure return, and using it as a supply will starve the next valve of pressure. Instead, use the N port (power beyond) for feeding pressure to subsequent valves in a series configuration.
Q6: Why does flow imbalance occur in a parallel hydraulic system?
In a parallel hydraulic valve setup, actuators compete for the same pump flow. Due to the path of least resistance, the actuator with the lighter load typically moves first, potentially causing flow imbalance. This behavior can be corrected using pressure-compensated flow control valves or load-sensing technology to ensure even flow distribution.
Q7: What type of hydraulic valve is best for sequential control of actuators?
To achieve sequential actuator control, use series-connected directional valves or integrate sequence valves in the system. A series hydraulic circuit naturally enforces order of movement, especially when combined with three-position six-way valves or tandem center spool designs that pass flow only after upstream demand is met.